NSE-8G™ Standard Product Data Sheet
Preliminary
Register 012H: Correct R8TD_RX_C1 Pulse Monitor
Bit
Bit 11:0
Type
R
Function
R8C1_OK_INT[11:0]
Default
0
R8C1_OK_INT[n]
This bit will be set to ‘1’ if both oc1fp[n] and r8_rx_c1[n] have occurred at the same time.
Otherwise, it will be stay at ‘0’. Read access will clear this bit.
Section 12.5 describes the proper use of this register.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-2010850, Issue 1