FRAME ENGINE AND DATA LINK MANAGER 32A256  
packet will cause the PMON Configurable Accumulator #1 register to  
increment. Transmit error-free packets are ignored when TP1EN is set low.  
RSPE2EN:  
The receive small packet error accumulate enable bit (RSPE2EN) enables  
counting of minimum packet size violation events. When RSPE2EN is set  
high, receipt of a packet that is shorter than 32 bits (CRC-CCITT, Unspecified  
CRC or no CRC) or 48 bits (CRC-32) will cause the PMON Configurable  
Accumulator #2 register to increment. Small packet errors are ignored when  
RSPE2EN is set low.  
RFCSE2EN:  
The receive frame check sequence error accumulate enable bit (RFCSE2EN)  
enables counting of receive FCS error events. When RFCSE2EN is set high,  
a mismatch between the received FCS code and the computed CRC residue  
will cause the PMON Configurable Accumulator #2 register to increment.  
Receive frame check sequence errors are ignored when RFCSE2EN is set  
low.  
RABRT2EN:  
The receive abort accumulate enable bit (RABRT2EN) enables counting of  
receive HDLC abort events. When RABRT2EN is set high, receipt of an abort  
code (at least 7 contiguous 2’s) will cause the PMON Configurable  
Accumulator #2 register to increment. Receive aborts are ignored when  
RABRT2EN is set low.  
RLENE2EN:  
The receive packet length error accumulate enable bit (RLENE2EN) enables  
counting of receive packet length error events. When RLENE2EN is set high,  
receipt of a packet that is longer than the programmable maximum or of a  
packet that in not octet aligned will cause the PMON Configurable  
Accumulator #2 register to increment. (Receipt of a packet that is both too  
long and not octet aligned results in only one increment.) Receive packet  
length errors are ignored when RLENE2EN is set low.  
RP2EN:  
The receive packet enable bit (RP2EN) enables counting of receive error-free  
packets. When RP2EN is set high, receipt of an error-free packet will cause  
the PMON Configurable Accumulator #2 register to increment. Receive error-  
free packets are ignored when RP2EN is set low.  