S/UNI-IMA-4 Telecom Standard Product Data Sheet
Released
Word Bits
Parameter
cid_invalid
Description
7
The Cell ID does not indicate the OAM Cell Type is ICP. This bit
should only be set when no ICP cells have been received on this
link.
6
5
label_invalid
lid_mm
The OAM Label does not indication IMA version 1.1.
The link identifier in the current ICP cell does not match the LID
in validation memory.
4
ima_id_mm
m_mm
The IMA ID in the current ICP cell does not match the IMA ID in
validation memory.
3
The IMA Frame Length in the current ICP cell does not match
the length in validation memory.
2
seq_error
The IMA Frame Sequence Number in the current ICP cell does
not match the sequence number maintained by the RDAT.
1
0
icp_offset_mm
stuff_invalid
The ICP Cell Offset in the current ICP cell does not match the
offset in validation memory.
The link stuff indication in the current ICP cell has not
progressed properly from the previous value.
13:15
Reserved.
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC-2020889, Issue 2