S/UNI-IMA-4 Telecom Standard Product Data Sheet
Released
Register 0x230: ICP Cell Forwarding Status Register
Bit
15:1
0
Type
R
R2C
Function
Reserved
PM_ICP_AVL
Default
0
0
This register serves as the current PM_ICP_AVL interrupt status.
PM_ICP_AVL
This bit is set by the RIPP state machine to indicate that there has been a new ICP cell
copied over to the ICP cell buffer register area. It is cleared upon the microprocessor
reading this register location.
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.
Document No.: PMC-2020889, Issue 2
196