622 Mbps ATM Traffic Management Device  
Table 5. Failure Conditions, Switch Fabric-to-ORT Interface (Continued)  
Fault Detected On g  
Action Taken  
Comment  
Parity fail.  
ACK sent out on h. Parity errored cell  
dropped. TX_PARITY_FAIL (refer to  
“TX_PARITY_FAIL” on page 111) sig-  
naled to the microprocessor.  
ACK already sent by the time the QRT  
has detected a parity error. In this case, a  
cell that was dropped was ACKed.  
3.2.4.5 Types of Failures and Their Manifestations  
Table 6 shows possible faults, their effects, and how they affect the network.  
Table 6. Faults and Effects on the Network  
Fault  
Manifestation  
Effect on Network  
Wire  
Connection  
Data line from SE_D_IN#(3:0) stuck at Invalid idle cell, cells with  
Port shut down ( interrupt gener-  
ated and backpressure withheld)  
on receipt of first 2 consecutive  
bad idle cells until condition is  
fixed, as port failure is sent to the  
source of data by lack of backpres-  
sure indication. If only one bad  
idel cell received, due to the  
round-trip delay between the QRT  
and the QSE, the source could  
send another (user) cell, causing  
the destination (QRT) to come out  
of the shut down state. This means  
the raw interrupt at QRT  
0 or 1.  
missing Cell Present and  
parity error.  
(SE_INPUT_PORT_FAIL) will  
be asserted and deasserted. The  
lateched interrupt  
(SE_INPUT_PORT_FAIL_LATC  
H) will still be asserted.  
SE_SOC_IN(3:0) line stuck at 0 or 1.  
Loss-of-lock on special cod- Port shut down until condition is  
ing on SE_SOC_IN(3:0).  
fixed, as port failure is sent to the  
source of data by lack of backpres-  
sure indication.  
BP_ACK_IN(3:0) line stuck at 0 or 1.  
Bridging fault within a port.  
Loss-of-lock on special cod- Port shut down until condition is  
ing on BP_ACK_IN(3:0).  
fixed.  
Invalid idle cell with some  
10/01 fail or parity error.  
Port shut down on receipt of first  
bad idle cell until condition is  
fixed, as port failure is sent to the  
source of data by lack of backpres-  
sure indication.  
53  
 