Registers 076H, 176H, 276H and 376H: RXCP Idle/Unassigned Cell Pattern:
H4 octet
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
CP[7]
CP[6]
CP[5]
CP[4]
CP[3]
CP[2]
CP[1]
CP[0]
0
0
0
0
0
0
0
0
CP[7:0]:
The CP[7:0] bits contain the idle/unassigned cell header pattern to match in
the fourth octet (H4) of the received cell in conjunction with the H4 octet
mask. The BLOCK bit, in the RXCP Control Register, determines whether to
block or pass cells matching this pattern. By default, unassigned cells are
transmitted. This register should be set to 01H to filter idle cells.