PM7340 S/UNI-IMA-8  
PRELIMINARY  
INVERSE MULTIPLEXING OVER ATM  
DATA SHEET  
PMC-2001723  
ISSUE 3  
INVERSE MULTIPLEXING OVER ATM  
shaking of state transitions between the near-end and far-end of an IMA  
connection.  
12.5.1 Issuing a RIPP Command  
The RIPP commands control the LSM and GSM state machines. The group is  
identified by the group tag and the links involved are identified with a 32-bit  
vector. The TX_LINK_VEC has one bit for each TX LID and bit 0 indicates TX  
LID 0 and bit 31 indicates TX LID31.  
For symmetrical operations, the RX LIDs are not known until the ICP cells from a  
link are validated, the user controls the relationship between physical links and  
the RX Link vector through the RX Physical Link Table in the RIPP Group  
Configuration record. The RX physical Link Table should be configured  
according to the TX LID values. For example, the physical link ID for the Link  
with TX LID = 0 should be programmed as the RX physical link 0. When using  
the RIPP commands, the physical link entered for RX physical link 0 will be  
controlled by bit 0 of the RX_LINK_VEC and the physical link entered for RX  
Physical link 31 in the table will be controlled by bit 31 of the RX_LINK_VEC.  
For asymmetric operations, since there is not a TX link for each possible RX link  
and the RX LIDs are not known until the ICP cells from a link are validated, the  
user controls the relationship between physical links and the RX Link vector  
through the RX Physical Link Table in the RIPP Group Configuration record.  
There are no restrictions on how this table should be configured in asymmetrical  
mode. When using the RIPP commands, the physical link entered for RX  
physical link 0 will be controlled by bit 0 of the RX_LINK_VEC and the physical  
link entered for RX Physical link 31 in the table will be controlled by bit 31 of the  
RX_LINK_VEC.  
Note: There are 31 entries in the RPHY table even through a maximum of 8 links  
may be in the group to account for the LID.  
The RIPP command procedure is as follows:  
1) Wait until the “CMD_BUSY” bit in the RIPP Command Register is clear.  
2) Once the CMD_BUSY bit is clear, write the necessary data for the  
command registers 0x222 - -x22C (RIPP CMD_WR_DATA1 through RIPP  
CMD WR_DATA3).  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  