PM7340 S/UNI-IMA-8
PRELIMINARY
INVERSE MULTIPLEXING OVER ATM
DATA SHEET
PMC-2001723
ISSUE 3
INVERSE MULTIPLEXING OVER ATM
the Indirect Memory Data registers. The address within a memory table can
be found in the Indirect Memory Address register.
MEM_BUSY:
The indirect memory access status bit (MEM_BUSY) reports the progress of
an indirect access. A write to the Indirect Memory Command register triggers
an indirect access and sets MEM_BUSY to a logic 1; MEM_BUSY will remain
logic 1 until the access is complete. This register should be polled to
determine when data from an indirect read operation is available in the TIMA
Indirect Memory Data registers or to determine when a new indirect write
operation may commence.
Register 0x322: TIMA Indirect Memory Address
Bit
Type
Function
Default
15:11
10:0
Unused
MEM_ADDR
0
0
R/W
This register provides the address for indirect memory access to the TIMA
Context tables.
MEM_ADDR:
The indirect memory address indicates the word address within the memory
table selected with the MEM_SELECT in the TIMA Indirect Memory
Command register.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
242