PM7340 S/UNI-IMA-8
PRELIMINARY
INVERSE MULTIPLEXING OVER ATM
DATA SHEET
PMC-2001723
ISSUE 3
INVERSE MULTIPLEXING OVER ATM
_defect
Cmd_data03:
Bit 0: rx link physical defect status
(LOS, LOF, AIS):
‘0’: no defect
‘1’: defect exists and need to be
reported to FE
The reset: Don’t care.
Cmd_data01: TX_LINK_VEC
Cmd_data02: RX_LINK_VEC
Cmd_data03:
Unusable_li 01100
nk
Group_tag
Bit 6:4: TX_CAUSE. Encoding:
“001”: No cause specified
“010”: Fault.
“011”: Mis-connected
“100”: Inhibited
“100”: Failed
Others: Reserved (no effect,
command void)
Bit 2:0: RX_CAUSE.
“001”: No cause specified
“010”: Fault.
“011”: Mis-connected
“100”: Inhibited
“100”: Failed
The reset: Don’t care.
Cmd_data01:
Bit 13: test pattern active indication
Update_test 10000
_ptn
Group_tag
Bit 12:8: LID value of the TX Link to
be tested.
Bit 7:0: Tx test pattern
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
196