欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM7340 参数 Datasheet PDF下载

PM7340图片预览
型号: PM7340
PDF下载: 下载PDF文件 查看货源
内容描述: S / UNI ATM反向多路复用, 8个环节 [S/UNI INVERSE MULTIPLEXING FOR ATM, 8 LINKS]
分类和应用: ATM集成电路SONET集成电路SDH集成电路电信集成电路电信电路异步传输模式
文件页数/大小: 334 页 / 2670 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM7340的Datasheet PDF文件第196页浏览型号PM7340的Datasheet PDF文件第197页浏览型号PM7340的Datasheet PDF文件第198页浏览型号PM7340的Datasheet PDF文件第199页浏览型号PM7340的Datasheet PDF文件第201页浏览型号PM7340的Datasheet PDF文件第202页浏览型号PM7340的Datasheet PDF文件第203页浏览型号PM7340的Datasheet PDF文件第204页  
PM7340 S/UNI-IMA-8  
PRELIMINARY  
INVERSE MULTIPLEXING OVER ATM  
DATA SHEET  
PMC-2001723  
ISSUE 3  
INVERSE MULTIPLEXING OVER ATM  
the group of which this link is a  
member.  
5
LODS_UNDERRU LODS, DCB underrun. Indicates that  
N_INT  
the DCB buffer experienced an  
underrun condition and has disabled  
itself from forwarding traffic to the ATM  
layer. An underrun occurs when the  
transport delay for the link is detected  
to be outside the programmed limit and  
the transport delay is smaller than the  
other links within the group In general,  
this will happen only if the transport  
delay of the link changes. An underrun  
condition requires that the link delay be  
revalidated prior to being placed back  
in service.  
This bit is reset immediately after the  
read_event command is executed for  
the group of which this link is a  
member.  
4
3
2
LCD_INT  
LIF_INT  
A change of state of the LCD status bit  
was detected.  
This bit is reset immediately after  
read_event command is executed for  
the group of which this link is a  
member.  
A change of state of the LIF status bit  
was detected.  
This bit is reset immediately after  
read_event command is executed for  
the group of which this link is a  
member.  
INVALID_ICP _INT Invalid ICP parameters detected on RX  
link during validation of the ICP cell  
parameters causing validation to fail.  
Possible reasons include:  
Invalid LID (i.e., duplicate).  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
183  