Register 0x158: Per-PHY RDI Cell Generation Control 2
Bit
31:16
15
14
13
12
11
10
9
8
7
6
5
Type
Function
Unused
RDI47
RDI46
RDI45
RDI44
RDI43
RDI42
RDI41
RDI40
RDI39
RDI38
RDI37
RDI36
RDI35
RDI34
RDI33
RDI32
Default
X
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
4
3
2
1
0
RDIx
RDIx enables the generation of RDI cells on a per-PHY basis for PHY x, where x is from 47
to 32. If RDIx is a logic 1, RDI cells for every connection (which is configured as an OAM
end point) associated with PHY x, are generated once per second (nominally) to the
Backwards Direction S/UNI-ATLAS-3200 via the Output Backwards Cell Interface.
Segment RDI will be generated at Segment End Points, and End-to-end RDI at end-to-end
points. Both kinds of cells will be generated at dual end points. If RDIx is a logic 0, RDI cell
generation on a per-PHY basis is disabled. The PHYID[5:0] field in the VC Table identifies a
connection’s associated PHY.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990553, Issue 4
266