S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet
Preliminary
Register 0x148: PHY Policing RAM Data Row 3
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Function
Default
PhyPoliceRow3[31]
PhyPoliceRow3[30]
PhyPoliceRow3[29]
PhyPoliceRow3[28]
PhyPoliceRow3[27]
PhyPoliceRow3[26]
PhyPoliceRow3[25]
PhyPoliceRow3[24]
PhyPoliceRow3[23]
PhyPoliceRow3[22]
PhyPoliceRow3[21]
PhyPoliceRow3[20]
PhyPoliceRow3[19]
PhyPoliceRow3[18]
PhyPoliceRow3[17]
PhyPoliceRow3[16]
PhyPoliceRow3[15]
PhyPoliceRow3[14]
PhyPoliceRow3[13]
PhyPoliceRow3[12]
PhyPoliceRow3[11]
PhyPoliceRow3[10]
PhyPoliceRow3[9]
PhyPoliceRow3[8]
PhyPoliceRow3[7]
PhyPoliceRow3[6]
PhyPoliceRow3[5]
PhyPoliceRow3[4]
PhyPoliceRow3[3]
PhyPoliceRow3[2]
PhyPoliceRow3[1]
PhyPoliceRow3[0]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
8
7
6
5
4
3
2
1
0
PHYPoliceRow3[31:0]
This is the 32-bits of data to be written into Row 3 of the per-PHY Policing RAM, or the data
read from Row 3 of the RAM when a read request has been completed. If data are to be
written into the RAM, then this register must be written to before the PHY Policing Access
and Control register is written. If data are to be read, then the BUSY bit of the PHY Policing
Access and Control register must be deasserted before these data are valid.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990553, Issue 4
258