PM6341 E1XC
DATA SHEET
PMC-910419
ISSUE 8
E1 FRAMER/TRANSCEIVER
Table 34
Symbol
-Transmit Pulse Symmetry
Parameter Min
Typ. Max Units Conditions
Positive/Ne
gative
5.0
%
Circuit per Figure 10,
Measured at
Pulse
transformer secondary.
Width
Imbalance
Positive/Ne
gative
5.0
%
Circuit per Figure 10,
Measured at
Pulse
transformer secondary.
Amplitude
Imbalance
Notes on Analog Specifications:
1. Typical Values are given as an aid to the system designer. Products are not
production tested to the typical values provided in the data sheet.
2. Parameter guaranteed by design not production tested.