bit error. Thus, the relationship between BER and BEE count becomes non-
-4
linear above a 10 BER. This must be taken into account when using ESF
CRC-6 counts to determine the BER.
The bit error rate for T1 ESF can be calculated from the one-second PMON
CRCE count by the following equation:
ꢁ
ꢀ
24
8000
24*193
.
.
/
/
ꢁ
log 1ꢂ
BEE
ꢀ
ꢀ
ꢀ
0 /
/
ꢀ
ꢀ
/
/
0
Bit Error Rate = 1 - 10
Figure 21
- CRCE Count vs. BER (T1 ESF mode)
1.00E-02
1.00E-03
1.00E-04
1.00E-05
1.00E-06
1.00E-07
0
50
100
150
200
250
300
350
CRCE
For T1 SF format, the CRCE and FER counts are identical, but the FER counter
is smaller and should be ignored.