型号: PM5363-BI
PDF下载: 下载PDF文件 查看货源
内容描述: SONET / SDH支路单元荷载处理器, 622兆比特/ s接口 [SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622 MBIT/S INTERFACES]
分类和应用: ATM集成电路SONET集成电路SDH集成电路电信集成电路电信电路异步传输模式
文件页数/大小: 459 页 / 3435 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM5363-BI的Datasheet PDF文件第51页浏览型号PM5363-BI的Datasheet PDF文件第52页浏览型号PM5363-BI的Datasheet PDF文件第53页浏览型号PM5363-BI的Datasheet PDF文件第54页浏览型号PM5363-BI的Datasheet PDF文件第56页浏览型号PM5363-BI的Datasheet PDF文件第57页浏览型号PM5363-BI的Datasheet PDF文件第58页浏览型号PM5363-BI的Datasheet PDF文件第59页  
PM5363 TUPP+622  
TUPP+622  
DATASHEET  
PMC-1981421  
ISSUE 4  
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622 MBIT/S  
INTERFACES  
Pin Name  
ITPL[3]  
Type  
Pin  
No.  
Function  
Input  
W20 The incoming tributary payload active #3  
(ITPL[3]) signal marks the bytes carrying the  
tributary payload for the STM-1 #3 stream when  
pointer interpreter bypass is enabled (PIBYP bit  
set high). When pointer interpreter bypass is  
disabled (PIBYP bit set low), ITPL[3] is ignored.  
Also, ITPL[3] is ignored when IPL[3] is low.  
In incoming STM-1 (STS-3) interface mode  
(IHSMODEB set high), ITPL[3] is set high to  
mark each tributary payload byte on the  
ID[23:16] bus. ITPL[3] is sampled on the rising  
edge of SCLK.  
In incoming STM-4 (STS-12) interface mode  
(IHSMODEB set low), ITPL[3] is unused and  
must be strapped low.  
ITPL[4]  
Input  
AA7 The incoming tributary payload active #4  
(ITPL[4]) signal marks the bytes carrying the  
tributary payload for the STM-1 #4 stream when  
pointer interpreter bypass is enabled (PIBYP bit  
set high). When pointer interpreter bypass is  
disabled (PIBYP bit set low), ITPL[4] is ignored.  
Also, ITPL[4] is ignored when IPL[4] is low.  
In incoming STM-1 (STS-3) interface mode  
(IHSMODEB set high), ITPL[4] is set high to  
mark each tributary payload byte on the  
ID[31:24] bus. ITPL[4] is sampled on the rising  
edge of SCLK.  
In incoming STM-4 (STS-12) interface mode  
(IHSMODEB set low), ITPL[4] is unused and  
must be strapped low.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
32  
 复制成功!