PM5363 TUPP+622
TUPP+622
DATASHEET
PMC-1981421
ISSUE 4
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622 MBIT/S
INTERFACES
Register 408H-40EH, 448H-44EH, 488H-48EH: RTTB, TU #2 in TUG2 #1 to
TUG2 #7, Configuration and Status
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
R
R
R/W
R/W
R
R/W
R
R/W
CONFIG[1]
CONFIG[0]
NOSYNC
LEN16
TIMV
1
1
0
0
X
0
X
0
TIME
TIUV
TIUE
This set of registers reports the status and configures the operational modes of
TU #2 in TUG2 #1 to TUG2 #7. These registers have no effect in TU3 mode.
When the corresponding TUG2 tributary group is configured to TU2 (VT6) mode,
the associated register in this set has no effect.
TIUE:
The TIUE bit enables trail trace identifier unstable interrupts for tributary
TU #2 in the corresponding TUG2. When TIUE is set high, an interrupt is
generated upon detection of an unstable identifier and upon return to a stable
identifier. Interrupts due to TIU status change are masked when TIUE is set
low.
TIUV:
The TIUV bit indicates the trail trace identifier unstable status of tributary
TU #2 in the corresponding TUG2.
TIME:
The TIME bit enables trail trace identifier mismatch interrupts for tributary
TU #2 in the corresponding TUG2. When TIME is set high, an interrupt is
generated upon detection of a mismatched identifier and upon return to a
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
302