Pm49FL002 / 004
PMC
AC CHARACTERISTICS (CONTINUED)
FWH/LPC RESET OPERATION CHARACTERISTICS
Symbol
TPRST
Parameter
Min
1
Max
Units
ms
µs
Reset Active Time to VCC Stable
Reset Active Time to Clock Stable
Reset Pulse Width
100
100
TKRST
TRSTP
TRSTF
ns
Reset Active to Output Float Delay
Reset Inactive Time to Input Active
50
ns
(1)
1
µs
TRST
Note: 1. There will be a 10 µs reset latency if a reset procedure is performed during a programming or erase
operation.
FWH/LPC RESET AC WAVEFORMS
TPRST
VC C
CLK
TKRST
TRSTP
RST#/INIT#
TRST
TRSTF
FWH[3:0] or
LAD[3:0]
FWH4 or
LFRAME#
A/A MUX MODE INPUT TEST MEASUREMENT CONDITION PARAMETERS
3.0 V
AC
Input
0.0 V
Measurement
Level
1.5 V
A/A MUX MODE TEST LOAD CONDITION
TO TESTER
TO DUT
CL
30 pF
Issue Date: December, 2003 Rev: 1.4
Programmable Microelectronics Corp.
39