Table 1: E1-FRMR Framing States  
State  
Out of Frame Out of Offline Frame  
FAS_Find_1  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
No  
No  
NFAS_Find  
FAS_Find_2  
BFA  
CRC to CRC Interworking  
FAS_Find_1_Par  
NFAS_Find_Par  
FAS_Find_2_Par  
BFA_Par  
CRC to non-CRC Interworking  
The states of the primary basic framer and the parallel/offline framer in the  
E1-FRMR block at each stage of the CRC multiframe alignment algorithm are  
shown in Table 1.  
From an out of frame state, the E1-FRMR attempts to find basic frame alignment  
in accordance with the FAS/NFAS/FAS G.706 Basic Frame Alignment procedure  
outlined above. Upon achieving basic frame alignment, a 400 ms timer is  
started, as well as an 8 ms timer. If two CRC multiframe alignment signals  
separated by a multiple of 2 ms are observed before the 8 ms timer has expired,  
CRC multiframe alignment is declared.  
If the 8 ms timer expires without achieving multiframe alignment, a new offline  
search for basic frame alignment is initiated. This search is performed in  
accordance with the Basic Frame Alignment procedure outlined above.  
However, this search does not immediately change the actual basic frame  
alignment of the system (i.e., PCM data continues to be processed in  
accordance with the first basic frame alignment found after an out of frame state  
while this frame alignment search occurs as a parallel operation).  
When a new basic frame alignment is found by this offline search, the 8 ms timer  
is restarted. If two CRC multiframe alignment signals separated by a multiple of  
2 ms are observed before the 8 ms timer has expired, CRC multiframe alignment  
is declared and the basic frame alignment is set accordingly (i.e., the basic frame  
alignment is set to correspond to the frame alignment found by the parallel offline  
search, which is also the basic frame alignment corresponding to the newly  
found CRC multiframe alignment).  
Subsequent expirations of the 8 ms timer will likewise reinitiate a new search for  
basic frame alignment. If, however, the 400 ms timer expires at any time during  
this procedure, the E1-FRMR stops searching for CRC multiframe alignment and  
declares CRC-to-non-CRC interworking. In this mode, the E1-FRMR may be  
PROPRIETARY AND CONFIDENTIAL  