Table 34: DS3 Receive Interface Timing
Symbol
Description
Min Max Units
RCLK Frequency
52
MHz
f
RCLK
t0
t1
RCLK minimum pulse width low
7.7
7.7
4
ns
ns
ns
ns
ns
ns
ns
RCLK
RCLK
RCLK minimum pulse width high
tS
RPOS/RDAT Set-up Time (See Note 1)
RPOS/RDAT Hold Time (See Note 2)
RNEG/RLCV Set-Up Time (See Note 1)
RNEG/RLCV Hold Time (See Note 2)
RPOS
tH
1
RPOS
RNEG
tS
tH
4
1
RNEG
tP
tP
tP
tP
RSCLK Edge to RDATO Prop Delay
2
12
12
12
11
RDATO
(See Notes 3 and 4)
RSCLK Edge to RFPO/RMFPO Prop Delay
(See Notes 3 and 4)
2
2
3
ns
ns
ns
RFPO
RSCLK Edge to ROVRHD Prop Delay
ROVRHD
RGAP
(See Notes 3 and 4)
RGAPCLK Edge to RDATO[x] Prop Delay
(See Notes 3 and 4)
Notes on DS3 Transmit Interface Timing:
1. When a set-up time is specified between an input and a clock, the set-up
time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4
Volt point of the clock.
2. When a hold time is specified between an input and a clock, the hold time is
the time in nanoseconds from the 1.4 Volt point of the clock to the 1.4 Volt
point of the input.
3. Output propagation delay time is the time in nanoseconds from the 1.4 Volt
point of the reference signal to the 1.4 Volt point of the output.
4. Maximum and minimum output propagation delays are measured with a 50
pF load on all the outputs.
PROPRIETARY AND CONFIDENTIAL