欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM4328-PI 参数 Datasheet PDF下载

PM4328-PI图片预览
型号: PM4328-PI
PDF下载: 下载PDF文件 查看货源
内容描述: 高密度T1 / E1成帧器,集成M13多路复用器 [HIGH DENSITY T1/E1 FRAMER WITH INTEGRATED M13 MULTIPLEXER]
分类和应用: 复用器数字传输控制器电信集成电路电信电路异步传输模式ATM
文件页数/大小: 250 页 / 1399 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM4328-PI的Datasheet PDF文件第147页浏览型号PM4328-PI的Datasheet PDF文件第148页浏览型号PM4328-PI的Datasheet PDF文件第149页浏览型号PM4328-PI的Datasheet PDF文件第150页浏览型号PM4328-PI的Datasheet PDF文件第152页浏览型号PM4328-PI的Datasheet PDF文件第153页浏览型号PM4328-PI的Datasheet PDF文件第154页浏览型号PM4328-PI的Datasheet PDF文件第155页  
STANDARD PRODUCT  
PM4328 TECT3  
DATASHEET  
PMC-2011596  
ISSUE 1  
HIGH DENSITY T1/E1 FRAMER  
AND M13 MULTIPLEXER  
Figure 28: FER Count vs. BER (E1 mode)  
9
8
7
Average Count Over  
Many 1 Second Intervals  
6
5
4
3
2
1
0
0
50  
100  
150  
200  
250  
Framing Bit Error Count Per Second  
Since the maximum number of CRC sub-multiframes that can occur in one  
second is 1000, the 10-bit FEBE and CRCE counters cannot saturate in one  
second. Despite this, there is not a linear relationship between BER and CRC-4  
-4  
block errors due to the nature of the CRC-4 calculation. At BERs below 10 ,  
there tends to be no more than one bit error per sub-multiframe, so the number  
of CRC-4 errors is generally equal to the number of bit errors, which is directly  
-4  
related to the BER. However, at BERs above 10 , each CRC-4 error is often  
due to more than one bit error. Thus, the relationship between BER and CRCE  
-4  
count becomes non-linear above a 10 BER. This must be taken into account  
when using CRC-4 counts to determine the BER. Since FEBEs are indications of  
CRCEs at the far end, and are accumulated identically to CRCEs, the same  
explanation holds for the FEBE event counter.  
The bit error rate for E1 can be calculated from the one-second PMON CRCE  
count by the following equation:  
8
8000  
8*256  
.
.
/
/
log 1  
CRCE  
 
0 /  
/
/
/
 
0
Bit Error Rate = 1 - 10  
PROPRIETARY AND CONFIDENTIAL  
138  