PE3XB Series 2.5 V
PECL Clock Oscillators
January 2008
Reliability: Environmental Compliance
Parameter
Condition
Mechanical Shock
Vibration
MIL-STD-883 Method 2002, Condition B
MIL-STD-883 Method 2007, Condition A
MIL-STD-883 Method 2003
Solderability
Thermal Shock
MIL-STD-883 Method 1011, Condition A
ESD Rating
Model
Minimum Voltage
Conditions
Human Body Model
Charged Device Model
1500
1000
MIL-STD-883 Method 3115
JESD 22-C101
Package Labeling
Label is 1" x 2.6" (25.4mm x 66.7mm)
Font is Courier New
Label is 1" x 2.6" (25.4mm x 66.7mm)
Font is Arial
Bar code is 39-Full ASCII
The label does show the PE3 full part number
Layout and application information
Recommend connecting Pad 1 and Pad 2 together to permit the design to accept Enable/Disable on both
input pads
For Optimum Jitter Performance, Pletronics recommends:
•
•
•
•
a ground plane under the device
no large transient signals (both current and voltage) should be routed under the device
do not layout near a large magnetic field such as a high frequency switching power supply
do not place near piezoelectric buzzers or mechanical fans.
www.pletronics.com
425-776-1880
5