ADBS-A350 Optical Finger Navigation  
AD_DTH_LOW  
Access: Read/Write  
Address: 0x71  
Reset Value: 0x3b  
7
6
5
4
3
2
1
0
Bit  
DTH_L  
DTH_L  
DTH_L  
DTH_L  
DTH_L  
DTH_L  
DTH_L  
DTH_L  
Field  
Data Type: Bit field  
USAGE: This register is used to set LOW speed De-assert shutter threshold.  
Field Name  
Description  
DTH_L 7:0  
Sets LOW speed de-assert threshold. Write in hexadecimal value.  
Formula (in decimal) = Shutter value / 8.  
It is recommended to have hysteresis of 60 to 100 between assert and  
de-assert threshold.  
QUANTIZE_CTRL  
Access: Read/Write  
Address: 0x72  
Reset Value: 0x99  
7
6
5
4
3
2
1
0
Bit  
YQ_ON  
YQ_DIV6  
YQ_DIV5  
YQ_DIV4  
XQ_ON  
XQ_DIV2  
XQ_DIV1  
XQ_DIV0  
Field  
Data Type: Bit field  
USAGE: This register is used to set quatization for Delta_X and Delta_Y. If both X and Y quantization modes are on, then  
only largest quantized X or Y will be reported.  
Field Name  
Description  
YQ_ON  
0 = Y quantization off  
1 = Y quantization On  
YQ_DIV6:4  
XQ_ON  
Quantization factor 2YQ_DIV . Reported YQ = DY / 2YQ_DIV  
.
0 = X quantization off  
1 = X quantization On  
XQ_DIV2:0  
Quantization factor 2XQ_DIV . Reported XQ = DX / 2XQ_DIV  
.
XYQ_THRESH  
Access: Read/Write  
Address: 0x73  
Reset Value: 0x02  
7
6
5
4
3
2
1
0
Bit  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
XYQ_M  
XYQ_C1  
XYQ_C0  
Field  
Data Type: Bit field  
USAGE: This register is used to set quatization gradient for DeltaX and DeltaY.  
Field Name  
Description  
XYQ_M  
Gradient of linear region  
0 = Gradient 1  
1 = Gradient 2  
XYQ_C1:0  
Indicates the offset of linear region (max of C = 3 or 0x03)  