UV light resistance  
DIN EN ISO 4892-2 and DIN EN ISO 60068-2-5  
In addition to infrared radiation, the solar  
leads to an impairment of the plastic's  
radiation affecting the surface of the earth mechanical property profile.  
has radiation ranges from the UV-A and  
Marking materials from Phoenix Contact  
UV-B spectrum. Depending on the plastic  
used, the UV-B part of the wavelength  
of 320 nm induces a more or less  
can be stored in dry as well as humid  
atmospheres under UV radiation and  
are tested in accordance with the  
aforementioned standards. The properties of  
the plastic and the legibility of the printings  
and labelings are checked after the test.  
strong molecular decomposition that is  
responsible for a considerable restriction  
of the plastic's mechanical property  
profile. Even the properties of printings  
and labelings can undergo damage to a  
greater or lesser extent due to this UV  
radiation, resulting in fading which can  
even lead to complete illegibility.  
If plastics and their printings and labelings  
are often subjected to day/night cycles  
outdoors, condensation may appear on  
the surface in the form of water droplets,  
which can act similarly to magnifying  
glasses when the sunshine returns, thus  
intensifying the radiation effect. The UV-B  
part of the solar spectrum in particular  
Aging test  
IEC 60947-7-1/-2  
Modular terminal blocks are characterized, Phoenix Contact marking materials are,  
among other things, by long life cycles and  
without exception, tested in accordance with  
their ability to safely withstand continuous IEC 60947-7-1/-2. All plastics used also have  
temperatures of +125°C. In order to  
ensure that the labeling of these terminal  
blocks also meets these requirements,  
Phoenix Contact uses labeling materials  
with heat stabilizers.  
sufficient safety reserves.  
To simulate usage over several years, the  
marking materials are subjected to  
temperature cycles together with the  
terminal blocks or conductors in the  
climate cabinet. The minimum  
temperature in the climate cabinet is set  
to 20°C and the maximum temperature to  
120°C (80°C with PVC). The test objects  
reach the maximum permissible operating  
temperature during the warming phase  
and the 10-minute pause phase. The  
cooling down phase follows. The test  
comprises a total of 192 cycles.  
T/°C  
t/min  
Temperature in  
relation to time  
Cycle