欢迎访问ic37.com |
会员登录 免费注册
发布采购

TDA8350Q 参数 Datasheet PDF下载

TDA8350Q图片预览
型号: TDA8350Q
PDF下载: 下载PDF文件 查看货源
内容描述: 直流耦合垂直偏转和东 - 西输出电路 [DC-coupled vertical deflection and East-West output circuit]
分类和应用:
文件页数/大小: 16 页 / 118 K
品牌: NXP [ NXP ]
 浏览型号TDA8350Q的Datasheet PDF文件第8页浏览型号TDA8350Q的Datasheet PDF文件第9页浏览型号TDA8350Q的Datasheet PDF文件第10页浏览型号TDA8350Q的Datasheet PDF文件第11页浏览型号TDA8350Q的Datasheet PDF文件第13页浏览型号TDA8350Q的Datasheet PDF文件第14页浏览型号TDA8350Q的Datasheet PDF文件第15页浏览型号TDA8350Q的Datasheet PDF文件第16页  
Philips Semiconductors  
Preliminary specification  
DC-coupled vertical deflection and  
East-West output circuit  
TDA8350Q  
specified storage maximum. If the printed-circuit board has  
been pre-heated, forced cooling may be necessary  
immediately after soldering to keep the temperature within  
the permissible limit.  
SOLDERING  
Plastic DIL-bent-SIL packages  
BY DIP OR WAVE  
The maximum permissible temperature of the solder is  
260 °C; this temperature must not be in contact with the  
joint for more than 5 s. The total contact time of successive  
solder waves must not exceed 5 s.  
REPAIRING SOLDERED JOINTS  
Apply the soldering iron below the seating plane (or not  
more than 2 mm above it). If its temperature is below  
300 °C, it must not be in contact for more than 10 s; if  
between 300 and 400 °C, for not more than 5 s.  
The device may be mounted up to the seating plane, but  
the temperature of the plastic body must not exceed the  
DEFINITIONS  
Data sheet status  
Objective specification  
Preliminary specification  
Product specification  
This data sheet contains target or goal specifications for product development.  
This data sheet contains preliminary data; supplementary data may be published later.  
This data sheet contains final product specifications.  
Limiting values  
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or  
more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation  
of the device at these or at any other conditions above those given in the Characteristics sections of the specification  
is not implied. Exposure to limiting values for extended periods may affect device reliability.  
Application information  
Where application information is given, it is advisory and does not form part of the specification.  
LIFE SUPPORT APPLICATIONS  
These products are not designed for use in life support appliances, devices, or systems where malfunction of these  
products can reasonably be expected to result in personal injury. Philips customers using or selling these products for  
use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such  
improper use or sale.  
January 1995  