PCA82C251T/N3 参数 Datasheet PDF下载

PCA82C251T/N3图片预览
型号: PCA82C251T/N3
PDF下载: 下载PDF文件 查看货源
内容描述: IC- SM -CAN接口\n [IC-SM-CAN INTERFACE ]
分类和应用: 网络接口电信集成电路电信电路光电二极管信息通信管理
文件页数/大小: 20 页 / 96 K
品牌: NXP [ NXP ]
 浏览型号PCA82C251T/N3的Datasheet PDF文件第12页浏览型号PCA82C251T/N3的Datasheet PDF文件第13页浏览型号PCA82C251T/N3的Datasheet PDF文件第14页浏览型号PCA82C251T/N3的Datasheet PDF文件第15页浏览型号PCA82C251T/N3的Datasheet PDF文件第17页浏览型号PCA82C251T/N3的Datasheet PDF文件第18页浏览型号PCA82C251T/N3的Datasheet PDF文件第19页浏览型号PCA82C251T/N3的Datasheet PDF文件第20页  
Philips Semiconductors  
Productspecification  
CAN transceiver for 24 V systems  
PCA82C251  
DEFINITIONS  
Data sheet status  
Objective specification  
Preliminary specification  
Product specification  
This data sheet contains target or goal specifications for product development.  
This data sheet contains preliminary data; supplementary data may be published later.  
This data sheet contains final product specifications.  
Limiting values  
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or  
more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation  
of the device at these or at any other conditions above those given in the Characteristics sections of the specification  
is not implied. Exposure to limiting values for extended periods may affect device reliability.  
Application information  
Where application information is given, it is advisory and does not form part of the specification.  
LIFE SUPPORT APPLICATIONS  
These products are not designed for use in life support appliances, devices, or systems where malfunction of these  
products can reasonably be expected to result in personal injury. Philips customers using or selling these products for  
use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such  
improper use or sale.  
BARE DIE DISCLAIMER  
All die are tested and are guaranteed to comply with all data sheet limits up to the point of wafer sawing for a period of  
ninety (90) days from the date of Philips’ delivery. If there are data sheet limits not guaranteed, these will be separately  
indicated in the data sheet. There are no post packing tests performed on individual die or wafer. Philips Semiconductors  
has no control of third party procedures in the sawing, handling, packing or assembly of the die. Accordingly, Philips  
Semiconductors assumes no liability for device functionality or performance of the die or systems after third party sawing,  
handling, packing or assembly of the die. It is the responsibility of the customer to test and qualify their application in  
which the die is used.  
2000 Jan 13  
16  