Philips Semiconductors
Product specification
Dual 4-channel analog multiplexer,
demultiplexer
74HC4052; 74HCT4052
Type 74HCT4052
GND = 0 V; tr = tf = 6 ns; CL = 50 pF.
TEST CONDITIONS
OTHER VCC (V) VEE (V)
SYMBOL
PARAMETER
MIN. TYP. MAX. UNIT
Tamb = −40 °C to +85 °C; note 1
tPHL/tPLH propagation delay Vis to Vos RL = ∞; see Fig.19
4.5
4.5
0
−
−
−
−
−
−
5
15
10
88
60
63
48
ns
ns
ns
ns
ns
ns
−4.5
0
4
tPZH/tPZL
turn-on time E, Sn to Vos
turn-off time E, Sn to Vos
RL = 1 kΩ; see Figs 20, 4.5
22 and 21
41
28
26
21
4.5
−4.5
0
tPHZ tPLZ
RL = 1 kΩ; see Figs 20, 4.5
22 and 21
4.5
−4.5
Tamb = −40 °C to +125 °C
tPHL/tPLH propagation delay Vis to Vos RL = ∞; see Fig.19
4.5
4.5
0
−
−
−
−
−
−
−
−
−
−
−
−
18
12
105
72
75
57
ns
ns
ns
ns
ns
ns
−4.5
0
tPZH/tPZL
turn-on time E, Sn to Vos
turn-off time E, Sn to Vos
RL = 1 kΩ; see Figs 20, 4.5
22 and 21
4.5
−4.5
0
tPHZ/tPLZ
RL = 1 kΩ; see Figs 20, 4.5
22 and 21
4.5
−4.5
Note
1. All typical values are measured at Tamb = 25 °C.
2004 Nov 11
15