NXP Semiconductors
74HC138-Q100; 74HCT138-Q100
3-to-8 line decoder/demultiplexer; inverting
10. Dynamic characteristics
Table 7.
Dynamic characteristics
Voltages are referenced to GND (ground = 0 V); C
L
= 50 pF unless otherwise specified; for test circuit see
Symbol Parameter
Conditions
T
amb
= 25
C
Min
For type 74HC138-Q100
t
pd
propagation An to Yn; see
delay
V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 5 V; C
L
= 15 pF
V
CC
= 6.0 V
E3 to Yn; see
V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 5 V; C
L
= 15 pF
V
CC
= 6.0 V
En to Yn; see
V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 5 V; C
L
= 15 pF
V
CC
= 6.0 V
t
t
transition
time
Yn; see
and
V
CC
= 2.0 V
V
CC
= 4.5 V
V
CC
= 6.0 V
C
PD
power
C
L
= 50 pF; f = 1 MHz;
dissipation
V
I
= GND to V
CC
capacitance
T
amb
=
40 C
to +85
C
Min
Max
T
amb
=
40 C
to +125
C
Min
Max
Unit
Typ
Max
-
-
-
-
-
-
-
-
-
-
-
-
41
15
12
12
47
17
14
14
47
17
14
14
150
30
-
26
150
20
-
26
150
20
-
26
-
-
-
-
-
-
-
-
-
-
-
-
190
38
-
33
190
38
-
33
190
38
-
33
-
-
-
-
-
-
-
-
-
-
-
-
225
45
-
38
225
45
-
38
225
45
-
38
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
-
-
-
-
19
7
6
67
75
15
13
-
-
-
-
-
95
19
16
-
-
-
-
-
110
22
19
-
ns
ns
ns
pF
74HC_HCT138_Q100
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2012. All rights reserved.
Product data sheet
Rev. 1 — 16 July 2012
8 of 18