Philips Semiconductors
Product specification
Octal buffer/line driver (3-State)
74ABT244
RECOMMENDED OPERATING CONDITIONS
LIMITS
SYMBOL
V
CC
V
I
V
IH
V
IL
I
OH
I
OL
∆t/∆v
T
amb
DC supply voltage
Input voltage
High-level input voltage
Low-level Input voltage
High-level output current
Low-level output current
Input transition rise or fall rate
Operating free-air temperature range
0
–40
PARAMETER
Min
4.5
0
2.0
0.8
–32
64
5
+85
Max
5.5
V
CC
V
V
V
V
mA
mA
ns/V
°C
UNIT
DC ELECTRICAL CHARACTERISTICS
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
T
amb
= +25°C
Min
V
IK
Input clamp voltage
V
CC
= 4.5V; I
IK
= –18mA
V
CC
= 4.5V; I
OH
= –3mA; V
I
= V
IL
or V
IH
V
OH
High-level output voltage
V
CC
= 5.0V; I
OH
= –3mA; V
I
= V
IL
or V
IH
V
CC
= 4.5V; I
OH
= –32mA; V
I
= V
IL
or V
IH
V
OL
I
I
I
OFF
I
PU/PD
I
OZH
I
OZL
I
CEX
I
O
I
CCH
I
CCL
I
CCZ
Quiescent supply current
su ly
Low-level output voltage
Input leakage current
Power-off leakage current
Power-up/down 3-State
output current
3
3-State output High current
3-State output Low current
Output HIgh leakage current
Short-circuit output current
1
V
CC
= 4.5V; I
OL
= 64mA; V
I
= V
IL
or V
IH
V
CC
= 5.5V; V
I
= GND or 5.5V
V
CC
= 0.0V; V
O
or V
I
≤
4.5V
V
CC
= 2.0V; V
O
= 0.5V; V
I
= GND or V
CC
;
V
OE
= Don’t care
V
CC
= 5.5V; V
O
= 2.7V; V
I
= V
IL
or V
IH
V
CC
= 5.5V; V
O
= 0.5V; V
I
= V
IL
or V
IH
V
CC
= 5.5V; V
O
= 5.5V; V
I
= GND or V
CC
V
CC
= 5.5V; V
O
= 2.5V
V
CC
= 5.5V; Outputs High, V
I
= GND or V
CC
V
CC
= 5.5V; Outputs Low, V
I
= GND or V
CC
V
CC
= 5.5V; Outputs 3-State;
V
I
= GND or V
CC
Outputs enabled, one data input at 3.4V,
other inputs at V
CC
or GND; V
CC
= 5.5V
∆I
CC
Additional supply current per
input pin
2
Outputs 3-State, one data input at 3.4V, other
inputs at V
CC
or GND; V
CC
= 5.5V
Outputs 3-State, one enable input at 3.4V,
other inputs at V
CC
or GND; V
CC
= 5.5V
–40
2.5
3.0
2.0
Typ
–0.9
2.9
3.4
2.4
0.42
±0.01
±5.0
±5.0
5.0
–5.0
5.0
–100
50
24
50
0.5
50
0.5
0.55
±1.0
±100
±50
50
–50
50
–180
250
30
250
1.5
250
1.5
–40
Max
–1.2
2.5
3.0
2.0
0.55
±1.0
±100
±50
50
–50
50
–180
250
30
250
1.5
250
1.5
T
amb
= –40°C
to +85°C
Min
Max
–1.2
V
V
V
V
V
µA
µA
µA
µA
µA
µA
mA
µA
mA
µA
mA
µA
mA
UNIT
NOTES:
1. Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
2. This is the increase in supply current for each input at 3.4V.
3. This parameter is valid for any V
CC
between 0V and 2.1V with a transition time of up to 10msec. For V
CC
= 2.1V to V
CC
= 5V
"
10%, a
transition time of up to 100µsec is permitted.
1998 Jan 16
4