PSAC60M Characteristics
Input:
AC Input Voltage Rating
100 to
240V
AC
WWW.PHIHONG.COM
Environmental:
Temperature
Operation
Non-operation
Humidity
0 to +40°C
-20 to +70°C
5 to 90%
AC Input Frequency
47 to 63Hz
Emissions
Input Current
1.5A at 120V AC
0.7A at 240V AC
FCC Part 15 Class B
EN55022 Class B
Immunity
Inrush Current
90A maximum at 100V AC
150A maximum at 240V AC
(Cold Start at ambient 25°C)
IEC61000-4-2
IEC61000-4-5
Level 4
Level 3
Over-Voltage Protection
Circuit will latch the auto-restart.
Leakage Current
3.5mA maximum at 254V AC and 60Hz
Over-Current Protection
Circuit will latch
Input Power Saving
< 0.5W at no load
Short-Circuit Protection
If output shorts then circuit will auto-restart
Output:
Output Power
60W maximum
Isolation
Primary to Secondary: 500V DC >7M OHM
Efficiency
Meets requirements for Level V marking
Dielectric Withstand (Hi-pot) Test
Primary to Secondary: 3000V AC for 1 min., 10mA
Dimension Diagram Unit: mm
DC Output Connector
2.1 x 5.5 x 9.5mm Center Positive Barrel