PSAC09R Characteristics
Input:
AC Input Voltage Rating
100 to 240V AC
125%, auto restart
WWW.PHIHONG.COM
Over Current Protection
Environmental:
Temperature
Operation
Non-operation
Humidity
0 to 40°C
-40 to 85°C
5 to 90%
AC Input Voltage Range
90 to 264V AC
AC Input Frequency
50 to 60Hz
Emissions
Input Current
0.3A (RMS) maximum at 115V AC
FCC Class B
EN55022 Class B
Leakage Current
0.25mA maximum at 240V AC
Immunity
EN50082-1:
EN61000-4-2
EN61000-4-5
Level 4
Inrush Current
60A maximum at 230VAC and maximum load
(cold start at ambient 25°C)
Insulation Resistance
Primary to Secondary: 100M ohm, 500V DC
Input Power Saving
<0.3W at 115/230V AC and no load
MTBF
100K hours minimum at maximum load, 240V AC
Output:
Efficiency
Meets Level V Efficiency Requirements
Dielectric Withstand (Hi-pot) Test
Primary to Secondary: 3000V AC for 1 min., 10mA
Hold-up Time
10mS minimum at 120V AC and maximum load
DC Output Connector
Micro USB
Over-Voltage Protection
Zener Clamping
Interchangeable Clips (sold separately)
RPA: N. America
PRB: Brazil
RPC: China
RPE: Europe
RPH: Korea
RPI: India
RPK: UK
RPN: Argentina
RPS: Australia
RPX: IEC320 C8
Dimension Diagram Unit: mm