WWW.PHIHONG.COM
PDA024A Characteristics
INPUT:
EMC
FCC Part 15 Class B
AC Input Voltage
90 to 132VAC
Immunity
EN61000-4-2
EN61000-4-4
EN61000-4-5
Nominal AC Input Voltage
110 to 120VAC
Leakage Current
<0.5mA at 120VAC and maximum load
Isolation Test
Primary to Secondary: 3000VAC, <10mA, 1 minute
Maximum Input Current
≤500mA at full load, 110VAC
Insulation Resistance
Primary to Secondary: 500VDC, >5M ohm, 1
minute
No-Load Power Draw
<300mW at 115VAC, 60Hz
FEATURES:
OUTPUT:
Total Output Power
24W maximum
Input Current Protection
The input power line will be fused with a 2A/250V
time-lag fuse
Efficiency
Short Circuit
≥82% at nominal input voltage, full load
Meets Level V efficiency marking requirements
Auto restart without damage
Output Overvoltage Protection
Output should not exceed voltage limits, auto shut
down
Power Factor
≥0.9 at nominal input voltage, full load
ENVIRONMENTAL:
AC Input
Operating Temperature
0 to +40°C
Fixed Blade (North America)
Storage Temperature
-40 to +85°C
DC Output
Operating Humidity
10 to 95%
2.1mm x 5.5mm x 9.5mm center positive barrel
Ingression Protection
IP20; plastic housing
Dimension Diagram Unit:mm