Release by
PARALIGHT DCC
SURFACE MOUNT DEVICE LED
Part No. : L-C192JGCT
REV: A/1
z Bin Code List
Luminous Intensity(IV), Unit:mcd@20mA
Forward Voltage(VF), Unit:V@20mA
Bin Code
Min
18.0
28.0
45.0
Max
28.0
45.0
71.0
Bin Code
Min
1.90
2.00
2.10
2.20
Max
2.00
2.10
2.20
2.30
M
N
P
4
5
6
7
Tolerance of each bin are±15%
Tolerance of each bin are±0.1Volt
Dominant Wavelength (Hue),Unit: nm@20mA
Bin Code
GA
Min
567.0
570.0
573
Max
570.0
573.0
576
GB
GC
Including±1nm test tolerance
Notes:
1. Luminous intensity is measured with a light sensor and filter combination that
proximities the CIE eye-response curve.
2. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous
intensity.
3. Caution in ESD :
Static Electricity and surge damages the LED. It is recommended use a wrist band or
anti-electrostatic glove when handling the LED. All devices, equipment and machinery
must be properly grounded.
4. Major standard testing equipment by “Instrument System” Model : CAS140B Compact
Array Spectrometer and “KEITHLEY” Source Meter Model : 2400.
DRAWING NO. : DS-75-08-0012
DATE : 2013-04-23
PAGE 4 of 14
PARA-FOR-068