ER3A~ER3J
RATING AND CHARACTERISTIC CURVES
100
AVERAGE FORWARD RECIFIED
CURRENT AMPERES
90
80
T
J
= 25 C
f = 1.0M
HZ
Vsig = 50mVp-p
O
3
CAPACITANCE, pF
70
60
50
40
30
20
10
0
0.1
1
10
100
1000
2
1
SINGLE PHASE, HALF-WAVE, 60Hz RESISTIVE
OR INDUCTIVE LOAD P.C.B MOUNTED
ON 0.3 x 0.3" (8.0 x 8.0 mm)COPPER PAD AREAS
0
20
40
60
80
100
120
O
0
140
160
180
REVERSE VOLTAGE, VOLTS
LEAD TEMPERATURE, C
FIG.1 TYPICAL JUNCTION CAPACITANCE
FIG.2 MAXIMUM AVERAGE FORWARD CURRENT RATING
1000
INSTANTANEOUS FORWARD CURRENT AMPERES
100
INVSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
100
T
J
= 125 C
O
50-200V
10
T
J
= 75 C
10
O
300-400V
1.0
600V
1.0
T
J
= 25 C
O
0.1
T
J
=25 C
PULSE WIDTH= 300
m
S
2% DUTY CYCLE
0.01
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
O
0.1
20
40
60
80
100
120
PERCENT OF RATED PEAK INVERSE VOLTGE, VOLTS
INSTANTANEOUS FORWARD VOLTAGE VOLTS
FIG.3 TYPICAL REVERSE CHARACTERISTICS
FIG.4 TYPICAL FORWARD CHARACTERISTICS
110
FORWARD SURGE CURRENT,
AMPERES
100
90
80
70
60
50
1
8.3ms SINGLE HALF SINE-WAVE
JEDC METHOD
5
10
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPEITIVE SURGE CURRENT
STAD-MAR.06.2009
PAGE . 2