SPECIFICATION CONTROL DRAWING
‘XY’ = WIRE GAUGE (AWG)
Product Dimensions
Product Revision
Product Name
Cable Dimensions
L
øA
øB
K
AWG
øD
øE
Color of
Item 4
J±0.5
max
min
min
min
max
min
(J±0.02)
D-101-33
D-101-34
D-101-35
D-101-36
J
K
J
22
22
20
20
black
white
black
white
17.0
(0.670)
4.30
(0.170)
5.00
(0.200)
150
(5.900)
4.30
(0.170)
1.78
(0.070)
7.00
(0.275)
J
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked polyvinylidene fluoride.
2. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Sn63 per ANSI-J-STD-006.
FLUX:
TYPE ROL1 per ANSI-J-STD-004.
THERMAL INDICATOR: red.
3. MELTABLE RINGS: Thermally stabilized thermoplastic. Color:gray.
4. GROUND LEAD: Raychem 55A0111-XY in accordance with MIL-W-22759/32 AWG ‘XY’ (see table) stranded
tin plated copper. Color: see table.
APPLICATION
1. These parts are designed to provide an environment protected shield termination on cables, rated for 125°C minimum, meeting the
dimensional criteria listed, having tin or silverplated copper shields.
2. Temperature range: -55°C to +150°C.
Install using Raychem-approved convection or infrared heating tools in accordance with Raychem process standard RCPS-100-70.
For best results, prepare the cable as shown:
* A trademark of TE Connectivity.
TITLE:
TE connectivity
300 Constitution Drive
Menlo Park, CA 94025
USA
THERMOFIT
DEVICES
SOLDERSLEEVE* DEVICE
WITH PRE-INSTALLED LEAD
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS.
INCHES DIMENSIONS ARE BETWEEN BRACKETS.
DOCUMENT NO.: D-101-3X
TOLERANCES:
0.00 N/A
0.0 N/A
ANGLES: N/A
TE Connectivity reserves the right to amend
this drawing at any time. Users should evaluate
the suitability of the product for their
application.
DCR NUMBER:
REPLACES:
D981004
D1013X
ROUGHNESS IN
MICRON
0 N/A
DRAWN BY:
DATE:
PROD. REV.
DOC ISSUE: SCALE:
SIZE:
A
SHEET:
1 of 1
M. FORONDA
06/15/98
SEE TABLE
5
None
Print Date: 11-May-11 If this document is printed it becomes uncontrolled. Check for the latest revision