ABSOLUTE MAXIMUM RATINGS
Parameter
Supply voltage
Supply current
Operating ambient temperature
Operating junction temperature
Storage temperature
Symbol
V
CC
I
CC
T
opr
T
j
T
stg
IN (Pin No.1)
Input Voltage Range
CNT (Pin No.3)
OUT (Pin No.5)
ESD
HBM (Human Body Model)
Rating
3.6
18
–20 to +70
–40 to +125
–55 to +125
—
– 0.3 to (V
CC
+0.3)
– 0.3 to (V
CC
+0.3)
1500
Unit
V
mA
°C
°C
°C
V
V
V
V
Note
*1
—
*2
*2
*2
*3
*4
*4
—
Notes). This product may sustain permanent damage if subjected to conditions higher than the above stated absolute maximum rating.
This rating is the maximum rating and device operating at this range is not guaranteeable as it is higher than our stated
recommended operating range.
When subjected under the absolute maximum rating for a long time, the reliability of the product may be affected.
*1:The values under the condition not exceeding the above absolute maximum ratings and the power dissipation.
*2:Except for the operating ambient temperature, operating junction temperature and storage temperature,
all ratings are for Ta = 25°C.
*3:RF signal input pin. Do not apply DC. Do not apply more than 0 dBm to RF input.
*4:(Vcc + 0.3) V must not be exceeded 3.6 V.
POWER DISSIPATION RATING
PACKAGE
SSMINI-5DC
θ
JA
833℃/W
PD (Ta=25℃)
0.12W
PD (Ta=70℃)
0.066W
Note). For the actual usage, please refer to the PD-Ta characteristics diagram in the package specification, supply
voltage, load and ambient temperature conditions to ensure that there is enough margin follow the power and
the thermal design does not exceed the allowable value.
CAUTION
Although this has limited built-in ESD protection circuit, but permanent damage may occur on it.
Therefore, proper ESD precautions are recommended to avoid electrostatic damage to the MOS gates
RECOMMENDED OPERATING CONDITIONS
Parameter
Supply voltage range
Symbol
V
CC
Min.
2.65
Typ.
2.8
Max.
2.95
Unit
V
Note
*1
Note) *1: The values under the condition not exceeding the above absolute maximum ratings and the power dissipation