“ZNR” Transient/Surge Absorbers (Type D)
■ Reference Guide to Standard Products
Maximum
Allowable
Voltage
Clamping
Voltage
at 8/20μs
Maximum
Peak Current
at 8/20μs(A)
Applicable
Standards
Varistor
✽
Voltage
Part No.
Recommended Applications
Standard
Approvals
(V)
ACrms (V) DC (V) max.(V) Ip (A) 1 time 2 times
Registration No.
△□
△□
△□
△□
△□
△□
△□
△□
△□
△□
△□
△□
△□
△□
△□
△□
△□
△□
ERZV10D751 V10751U ○●☆★
ERZV14D751 V14751U ○◎☆★
ERZV20D751 V20751U ○◎☆★
ERZV10D821 V10821U ○●☆★
ERZV14D821 V14821U ○◎☆★
ERZV20D821 V20821U ○◎☆★
ERZV10D911 V10911U ○●☆★
ERZV14D911 V14911U ○◎☆★
ERZV20D911 V20911U ○◎☆★
ERZV10D102 V10102U ○●☆★
ERZV14D102 V14102U ○◎☆★
ERZV20D102 V20102U ○◎☆★
ERZV10D112 V10112U ○●☆★
ERZV14D112 V14112U ○◎☆★
ERZV20D112 V20112U ○◎☆★
ERZV10D182CS V10182U ○●☆★
ERZV14D182CS V14182U ○◎☆★
ERZV20D182 V20182U ○◎☆★
1240
1240
1240
1355
1355
1355
1500
1500
1500
1650
1650
1650
1815
1815
1815
2970
2970
2970
25
50
3500
5000
7500
3500
5000
7500
3500
5000
7500
3500
5000
7500
3500
5000
7500
3500
5000
7500
2500
4500
6500
2500
4500
6500
2500
750
(675 to 825)
460
510
615
670
AC 380 V, Line–Line and
Line–Ground Applications
(For DC 500 V Insulating Test)
100
25
820
(738 to 902)
50
100
25
AC 415 V, Line–Line and
910
(819 to 1001)
550
745
50
4500 Line–Ground Applications
(For DC 500 V Insulating Test)
100
25
6500
2500
4500
1000
(900 to 1100)
625
825
50
AC 480 V, Line–Line and
Line–Ground Applications
(For DC 500 V Insulating Test)
100
25
6500
2500
1100
(990 to 1210)
680
895
50
4500
6500
100
25
2500
Line–Ground Applications
1800
(1700 to 1980)
1000
1465
50
4500 (For AC 1200 V Withstanding
Test)
100
6500
Measuring Current of Varistor Voltage 5 Series : 0.1 mA, Others: 1 mA
✽
: UL1449 Ed.3,
: UL1449 Type3 (or Code-Connected and Direct plug-in),
: UL1449 Type2 (or Permanently Connected),
◎
○
☆
※
●
: VDE (IEC61051-1, -2, -2-2),
: VDE (IEC60950-1 Ed.2 Annex.Q), △ : UL1414, □ : CSA C22.2 No.1, – : None
★
Approval number (File No.) of safety regulations are subject to revision without notice. Ask factory for a copy of the latest file No.
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
01 Aug. 2012
– 8 –