USER GUIDE  
Included in this box  
ATG Electronics iBright™ I38i T8 LED Tube (G3 IPS US), 1 Pc  
User Guide, 1 set  
Red-Black Wires, 2 PCs  
Wire Nuts, 4 PCs  
Note:  
Please read this entire manual to fully understand and safety use this product.  
Specifications are subject to change without notice. Please visit www.atgelectronics.com for the most recent user guide versions.  
Warning  
WARNING Risk of fire or electric shock. iBright™ I38i T8 LED Tube installation requires knowledge of luminaires electrical systems. If not  
qualified, do not attempt installation. Contact a qualified electrician.  
WARNING Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the  
photographs and/or drawings.  
WARNING To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.  
Lamp replacement instructions shall indicate the manufacturer's custom lamp part number, and a method to order replacement lamps by  
phone, website and/or mail. These instructions shall be included on an information sheet packaged with each unit.  
Retrofit Luminaire with Electronic Ballast  
Installation Steps  
Step 1:Turn off main power before installation.  
For safety, make sure main power source is switched off before attempting to install.  
Step 2:Take off existing fluorescent light and disconnect the ballast.  
Step 3: Cut four leads of G13 lamp holders. (For detailed placement of the cuts, note the X’s on the wiring diagram labeled “Before” shown  
below.)  
Step 4: Reconnect lamp holder leads L and N to the supply wires of branch circuit according to the wiring diagram below. Both G13 sockets of  
the fixture should be connected to the power source directly.  
Step 5: Install fixture as before.  
Step 6: Adhere a label to the luminaire to the effect of “This luminaire has been modified and can no longer operate fluorescent lamps.” on the  
retrofitted luminaire, where readily visible during relamping.  
Step 7: Install the iBright™ LED tube into the fixture.  
Step 8: Turn on the power.  
www.atgelectronics.com Toll free: 877-461-5333