Output (4)
Ripple & Noise
Eff (4)
Load
(%) regulation
Input Current
No load(3) Full load(2)
Output Current
Model
Number
Input
Range
Output
Voltage
Min. load Full load
0mA
0mA
0mA
0mA
87
89
89
89
84
86
88
90
90
90
QEB125-24S3P3 18 – 36 VDC
3.3 VDC
5 VDC
30A
25A
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
100mVp-p
130mA
180mA
190mA
190mA
60mA
4970mA
6127mA
6129mA
6125mA
1641mA
2223mA
2455mA
3028mA
3029mA
3027mA
10mV
15mV
36mV
45mV
5.4mV
7.5mV
10mV
15mV
36mV
45mV
QEB125-24S05
QEB125-24S12
QEB125-24S15
18 – 36 VDC
18 – 36 VDC
18 – 36 VDC
12 VDC
15 VDC
1.8 VDC
2.5 VDC
3.3 VDC
5 VDC
10.42A
8.33A
35A
QEB125-48S1P8 36 – 75 VDC
QEB125-48S2P5 36 – 75 VDC
QEB125-48S3P3 36 – 75 VDC
0mA
0mA
0mA
0mA
0mA
0mA
35A
60mA
30A
90mA
QEB125-48S05
QEB125-48S12
QEB125-48S15
36 – 75 VDC
36 – 75 VDC
36 – 75 VDC
25A
90mA
12 VDC
15 VDC
10.42A
8.33A
130mA
130mA
Note :
1.BELLCORE TR-NWT-000332. Case 1: 80% Stress, Temperature at 40ºC.
MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment)
2.Maximum value at nominal input voltage and full load of standard type.
3.Typical value at nominal input voltage and no load.
4.Typical value at nominal input voltage and full load.
5.Maximum output deviation is 10% inclusive of trim. If remote sense is not being used, the + sense should be connected to its corresponding
+OUTPUT and likewise the –sense should be connected to its corresponding –OUTPUT.
6.The positive logic and pin length are optional ( see table ). The pin voltage is referenced to –Vin.
7.Heat sink is optional and P/N:7G-0029A-F, 7G-0030A-F, 7G-0031A-F, 7G-0032A-F.
8.The QEB125 meets EN55022 class A and class B only with external components connected before the input pin to the converter.
9.An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220μF/100V, ESR 48mΩ.
10.BASEPLATE GROUNDING:Base-plate should be grounded at one of the four screw bolts prior to operation.
11.The converter is provided by basic insulation.
Page 2 of 4 Issued Date:2008/05/21