Model
Number
Input
Range
Output
Voltage
3.3 VDC
5 VDC
Output Current
Min. load Full load
Output (4)
Ripple & Noise
75mVp-p
Input Current
Eff (4) Capacitor (5)
No load(3) Full load(2)
(%)
89
90
90
90
89
90
90
90
Load max
36000μF
20400μF
3550μF
FEC60-24S3P3 18 – 36 VDC
FEC60-24S05 18 – 36 VDC
FEC60-24S12 18 – 36 VDC
FEC60-24S15 18 – 36 VDC
FEC60-48S3P3 36 – 75 VDC
FEC60-48S05 36 – 75 VDC
FEC60-48S12 36 – 75 VDC
FEC60-48S15 36 – 75 VDC
0mA
0mA
0mA
0mA
0mA
0mA
0mA
0mA
14000mA
12000mA
5000mA
4000mA
14000mA
12000mA
5000mA
4000mA
100mA
130mA
150mA
150mA
80mA
2264mA
2941mA
2907mA
2907mA
1132mA
1453mA
1453mA
1453mA
75mVp-p
12 VDC
15 VDC
3.3 VDC
5 VDC
100mVp-p
100mVp-p
75mVp-p
2300μF
36000μF
20400μF
3550μF
75mVp-p
90mA
12 VDC
15 VDC
100mVp-p
100mVp-p
100mA
100mA
2300μF
Note
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40ºC.
MIL-HDBK-217F Notice2 @Ta=25 ºC, Full load(Ground, Benign, controlled environment)
2. Maximum value at nominal input voltage and full load.
3. Typical value at nominal input voltage and no load.
4. Typical value at nominal input voltage and full load.
5. Test by minimum Vin and constant resistive load.
6. Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +sense should be connected to its
corresponding +OUTPUT and likewise the -sense should be connected to its corresponding –OUTPUT.
7. The ON/OFF control pin voltage is referenced to –Vin.
To order negative logic ON/OFF control add the suffix-N (Ex: FEC60-48S05-N).
8. Test condition with vertical direction by natural convection.
9. Heat sink is optional and P/N:7G-0026C-F.
10. The FEC60 series can meet EN55022 Class A with parallel an external capacitor to the input pins.
Recommend: 24Vin : 6.8μF/50V 1812 MLCC
48Vin : 2.2μF/100V*2 PCS 1812 MLCC.
11. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220μF/100V, ESR 48mΩ.
FEC60-48S05 DERATING CURVE
WITH HEATSINK (Note 5 )
(Note 9)
FEC60-48S05 DERATING CURVE
120
100
80
60
40
20
0
120
100
80
60
40
20
0
-40
-20
0
20
40
40
60
80
100
120
-40
-20
0
20
40
60
80
100
120
54
AMBIENT TEMPERATURE(
)
℃
AMBIENT TEMPERATURE(
)
℃
FEC60-48S05
Efficiency VS Output Load
FEC60-48S05
Efficiency VS Input voltage
95
90
85
80
75
70
65
60
92
91
90
89
88
87
86
85
36
40
44
48
52
56
60
64
68
72
10
20
30
40
50
60
70
80
90
100
INPUT VOLTAGE(V)
OUTPUT LOAD (% of Full Load)
Page 2 of 3 Issued Date:2008/06/12