Page No. : 6/10
 
Fig.2. Auxiliary voltage waveform 
 
Via a resistor divider connected between the auxiliary winding and INV (pin 3), the auxiliary voltage is sampled at the end of 
the demagnetization and it is hold until the next sampling. 
 
The sampled voltage is compared with V
REF
 (2.0V) and the error is amplified. The error amplifier output COMP reflects the 
load condition and controls the PWM switching frequency to regulate the output voltage, thus constant output voltage can 
be achieved. 
 
When sampled voltage is below V
REF
 and the error amplifier output COMP reaches its maximum, the switching frequency is 
controlled by the sampled voltage thus the output voltage to regulate the output current, thus the constant output current 
can be achieved. 
 
Adjustable CC point and Output Power 
In RS2135, the CC point and maximum output power can be externally adjusted by external current sense resistor R
S
 at CS pin 
as  illustrated  in  Typical  Application  Diagram.  The  output  power  is  adjusted  through  CC  point  change.  The  larger  R
S
,  the 
smaller CC point is, and the smaller output power becomes, and vice versa as shown in Fig.3. 
 
Fig.3. Adjustable output power by changing R
S
 
 
 
Operation switching frequency 
The switching frequency of RS2135 is adaptively controlled according to the load conditions and the operation modes. No 
external frequency setting components are required. The operation switching frequency at maximum output power is set to 
60KHz internally. 
 
For flyback operating in DCM, The maximum output power is given by 
1
P
O
MAX
= ×
L
P
×
F
SW
×
I
P
2
 
2
Where L
indicate the inductance of primary winding and I
P
 is the peak current of primary winding. 
 
DS‐RS2135‐03 
   
September,
 2009 
www.Orister.com