2.5.Lighting Specifications
2.5.1.Absolute Maximum Ratings
Ta=25℃
Units
V
Parameter
Symbol
VR
Conditions
Note 1
-
Min.
-
Typ.
-
Max.
8.0
Reverse Voltage
LED Power Dissipation
PD
-
-
700
mW
Note 1 : VF is defined as the voltage between ANODE and CATHODE as shown below.
VLED
R
VF
I
F
VSS
2.5.2.Operating Characteristics
Ta=25℃
Units
mA
Parameter
Foward Current
Luminance of
Symbol
Conditions
VF=5.0V
VF=5.0V
Min.
50
Typ.
80
Max.
100
-
IF
L
35
-
cd/㎡
Backlight Surface
DMC-50149NYU-LY-B (AB) No.98-0118
OPTREX CORPORATION
Page 6/16