NCP59150, NCV59150 Series
ABSOLUTE MAXIMUM RATINGS
Symbol
V
IN
V
EN
V
FLG
V
OUT
– V
IN
P
D
T
J
T
S
Supply Voltage
Enable Input Voltage
Error Flag Open Collector Output Maximum Voltage
Reverse V
OUT
– V
IN
Voltage (EN = Shutdown or Vin = 0 V) (Note 1)
Power Dissipation (Notes 2 and 5)
Junction Temperature
Storage Temperature
ESD Rating (Notes 3 and 4)
Human Body Model
Machine Model
Rating
Value
0 to 18
0 to 18
0 to 18
0 to 6.5
Internally Limited
−40
v
T
J
v
+125
−65
v
T
J
v
+150
2000
200
C
C
V
Unit
V
V
V
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
NOTE: All voltages are referenced to GND pin unless otherwise noted.
1. The ENABLE pin input voltage must be
0.8 V or Vin must be connected to ground potential.
2. P
D(max)
= (T
J(max)
– T
A
) / R
qJA
, where R
qJA
depends upon the printed circuit board layout.
3. Devices are ESD sensitive. Handling precautions recommended..
4. This device series incorporates ESD protection and is tested by the following methods:
ESD Human Body Model (HBM) tested per AEC−Q100−002 (EIA/JESD22−A114C)
ESD Machine Model (MM) tested per AEC−Q100−003 (EIA/JESD22−A115C)
This device contains latch−up protection and exceeds 100 mA per JEDEC Standard JESD78.
5. This protection is not guaranteed outside the Recommended Operating Conditions.
RECOMMENDED OPERATING CONDITIONS
(Note 6)
Symbol
V
IN
V
EN
V
FLG
T
J
Supply Voltage
Enable Input Voltage
Error Flag Open Collector Voltage
Junction Temperature
Rating
Value
2.24 to 13.5
0 to 13.5
0 to 13.5
−40
v
T
J
v
+125
Unit
V
V
V
C
6. The device is not guaranteed to function outside it’s Recommended operating conditions.
http://onsemi.com
3