MUR405, MUR410, MUR415, MUR420, MUR440, MUR460
MAXIMUM RATINGS
MUR
405 410 415 420 440 460
50 100 150 200 400 600
Rating
Symbol
Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
V
RRM
V
RWM
V
R
Average Rectified Forward Current (Square Wave)
(Mounting Method #3 Per Note 2)
I
4.0 @ T = 80°C
4.0 @
T = 40°C
A
A
A
F(AV)
A
Nonrepetitive Peak Surge Current
I
125
110
FSM
(Surge applied at rated load conditions, half wave, single phase, 60 Hz)
Operating Junction Temperature & Storage Temperature
T , T
*65 to +175
°C
J
stg
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
THERMAL CHARACTERISTICS
MUR
405 410 415 420 440 460
Rating
Symbol
Unit
Maximum Thermal Resistance, Junction−to−Ambient
R
q
JA
See Note 2
°C/W
ELECTRICAL CHARACTERISTICS
Rating
MUR
405 410 415 420 440 460
Symbol
Unit
Maximum Instantaneous Forward Voltage (Note 1)
v
V
F
(i = 3.0 A, T = 150°C)
0.71
0.88
0.89
1.05
1.25
1.28
F
J
(i = 3.0 A, T = 25°C)
F
J
(i = 4.0 A, T = 25°C)
F
J
Maximum Instantaneous Reverse Current (Note 1)
i
mA
R
(Rated dc Voltage, T = 150°C)
150
5
250
10
J
(Rated dc Voltage, T = 25°C)
J
Maximum Reverse Recovery Time
t
rr
t
fr
ns
(I = 1.0 A, di/dt = 50 A/ms)
35
25
75
50
F
(I = 0.5 A, i = 1.0 A, I = 0.25 A)
F
R
REC
Maximum Forward Recovery Time
25
50
ns
(I = 1.0 A, di/dt = 100 A/ms, Recovery to 1.0 V)
F
Controlled Avalanche Energy (Maximum)
W
aval
5
mJ
1. Pulse Test: Pulse Width = 300 ms, Duty Cycle v 2.0%.
http://onsemi.com