MUR405, MUR410, MUR415, MUR420, MUR440, MUR460
MAXIMUM RATINGS
MUR
Rating
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
Average Rectified Forward Current (Square Wave)
(Mounting Method #3 Per Note 2)
Nonrepetitive Peak Surge Current
(Surge applied at rated load conditions, half wave, single phase, 60 Hz)
Operating Junction Temperature & Storage Temperature
Symbol
V
RRM
V
RWM
V
R
I
F(AV)
I
FSM
T
J
, T
stg
405
50
410
100
415
150
420
200
440
400
460
600
Unit
V
4.0 @ T
A
= 80°C
125
*65
to +175
4.0 @
T
A
= 40°C
110
A
A
°C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
THERMAL CHARACTERISTICS
MUR
Rating
Maximum Thermal Resistance, Junction−to−Ambient
Symbol
R
qJA
405
410
415
420
440
460
Unit
°C/W
See Note 2
ELECTRICAL CHARACTERISTICS
MUR
Rating
Maximum Instantaneous Forward Voltage (Note 1)
(i
F
= 3.0 A, T
J
= 150°C)
(i
F
= 3.0 A, T
J
= 25°C)
(i
F
= 4.0 A, T
J
= 25°C)
Maximum Instantaneous Reverse Current (Note 1)
(Rated dc Voltage, T
J
= 150°C)
(Rated dc Voltage, T
J
= 25°C)
Maximum Reverse Recovery Time
(I
F
= 1.0 A, di/dt = 50 A/ms)
(I
F
= 0.5 A, i
R
= 1.0 A, I
REC
= 0.25 A)
Maximum Forward Recovery Time
(I
F
= 1.0 A, di/dt = 100 A/ms, Recovery to 1.0 V)
Controlled Avalanche Energy (Maximum)
1. Pulse Test: Pulse Width = 300
ms,
Duty Cycle
v
2.0%.
Symbol
v
F
0.71
0.88
0.89
i
R
150
5
t
rr
35
25
t
fr
W
aval
25
5
75
50
50
ns
mJ
250
10
ns
1.05
1.25
1.28
mA
405
410
415
420
440
460
Unit
V
http://onsemi.com
2