LM339, LM239, LM2901, LM2901V, NCV2901, MC3302
MAXIMUM RATINGS
Rating
Power Supply Voltage
LM239/LM339/LM2901, V
MC3302
Input Differential Voltage Range
LM239/LM339/LM2901, V
MC3302
Input Common Mode Voltage Range
Output Short Circuit to Ground (Note 1)
Power Dissipation @ T
A
= 25°C
Plastic Package
Derate above 25°C
Junction Temperature
Operating Ambient Temperature Range
LM239
MC3302
LM2901
LM2901V, NCV2901
LM339
Storage Temperature Range
ESD Protection at any Pin (Note 2)
Human Body Model
Machine Model
T
stg
V
ESD
1500
200
V
ICMR
I
SC
P
D
1/R
qJA
T
J
T
A
−25 to +85
−40 to +85
−40 to +105
−40 to +125
0 to +70
−65 to +150
°C
V
1.0
8.0
150
W
mW/°C
°C
°C
V
IDR
36
30
−0.3 to V
CC
Continuous
Vdc
Symbol
V
CC
Value
+36 or
±18
+30 or
±15
Vdc
Unit
Vdc
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. The maximum output current may be as high as 20 mA, independent of the magnitude of V
CC
. Output short circuits to V
CC
can cause excessive
heating and eventual destruction.
2. V
ESD
rating for NCV/SC devices is: Human Body Model − 2000 V; Machine Model − 200 V.
V
CC
+ Input
− Input
Output
GND
NOTE: Diagram shown is for 1 comparator.
Figure 1. Circuit Schematic
http://onsemi.com
2