LM324, LM324A, LM224, LM2902, LM2902V, NCV2902
MAXIMUM RATINGS (T = +25°C, unless otherwise noted.)
A
Rating
Symbol
Value
Unit
Power Supply Voltages
Single Supply
Vdc
V
32
16
CC
, V
Split Supplies
V
CC
EE
Input Differential Voltage Range (Note 1)
Input Common Mode Voltage Range (Note 2)
Output Short Circuit Duration
V
V
32
−0.3 to 32
Continuous
150
Vdc
Vdc
IDR
ICR
SC
t
Junction Temperature
T
°C
J
Thermal Resistance, Junction−to−Air (Note 3)
Case 646
Case 751A
Case 948G
R
118
156
190
°C/W
ꢀ
JA
Storage Temperature Range
T
stg
−65 to +150
°C
ESD Protection at any Pin
Human Body Model
Machine Model
V
esd
V
2000
200
Operating Ambient Temperature Range
T
A
°C
LM224
LM324, 324A
−25 to +85
0 to +70
LM2902
LM2902V, NCV2902 (Note 4)
−40 to +105
−40 to +125
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. Split Power Supplies.
2. For supply voltages less than 32 V, the absolute maximum input voltage is equal to the supply voltage.
3. All R
measurements made on evaluation board with 1 oz. copper traces of minimum pad size. All device outputs were active.
ꢀ
JA
4. NCV2902 is qualified for automitive use.
http://onsemi.com