 浏览型号ADM1032ARMZ-2R的Datasheet PDF文件第10页浏览型号ADM1032ARMZ-2R的Datasheet PDF文件第11页浏览型号ADM1032ARMZ-2R的Datasheet PDF文件第12页浏览型号ADM1032ARMZ-2R的Datasheet PDF文件第13页浏览型号ADM1032ARMZ-2R的Datasheet PDF文件第14页浏览型号ADM1032ARMZ-2R的Datasheet PDF文件第16页浏览型号ADM1032ARMZ-2R的Datasheet PDF文件第17页浏览型号ADM1032ARMZ-2R的Datasheet PDF文件第18页  
ADM1032  
Layout Considerations  
microphone cable. Connect the twisted pair to D+  
and Dand the shield to GND close to the  
ADM1032. Leave the remote end of the shield  
unconnected to avoid ground loops.  
Digital boards can be electrically noisy environments, and  
the ADM1032 is measuring very small voltages from the  
remote sensor, so care must be taken to minimize noise  
induced at the sensor inputs. The following precautions  
should be taken.  
Because the measurement technique uses switched  
current sources, excessive cable and/or filter capacitance  
can affect the measurement. When using long cables, the  
filter capacitor can be reduced or removed.  
Cable resistance can also introduce errors. 1 W series  
resistance introduces about 1°C error.  
1. Place the ADM1032 as close as possible to the  
remote sensing diode. Provided that the worst  
noise sources, that is, clock generators,  
data/address buses, and CRTs, are avoided, this  
distance can be four to eight inches.  
2. Route the D+ and Dtracks close together, in  
parallel, with grounded guard tracks on each side.  
Provide a ground plane under the tracks if  
possible.  
Power Sequencing Considerations  
Power Supply Slew Rate  
When powering up the ADM1032 you must ensure that  
the slew rate of V is less than 18 mV/ms. A slew rate larger  
DD  
3. Use wide tracks to minimize inductance and  
reduce noise pickup. 10 mil track minimum width  
and spacing is recommended.  
than this may cause poweronreset issues and yield  
unpredictable results.  
THERM Pin Pullup  
As mentioned above, the THERM signal is open drain and  
10MIL  
10MIL  
GND  
D+  
requires a pullup to V . The THERM signal must always  
DD  
be pulled up to the same power supply as the ADM1032,  
unlike the SMBus signals (SDA, SCL and ALERT) that can  
be pulled to a different power rail. The only time the  
THERM pin can be pulled to a different supply rail (other  
10MIL  
10MIL  
10MIL  
10MIL  
10MIL  
than V ) is if the other supply is powered up simultaneous  
DD  
D–  
with, or after the ADM1032 main V . This is to protect the  
DD  
internal circuitry of the ADM1032. If the THERM pullup  
supply rail were to rise before V , the POR circuitry may  
DD  
GND  
not operate correctly.  
Application Circuit  
Figure 18. Typical Arrangement of Signal Tracks  
Figure 20 shows a typical application circuit for the  
ADM1032, using a discrete sensor transistor connected via  
a shielded, twisted pair cable. The pullups on SCLK,  
SDATA, and ALERT are required only if they are not  
already provided elsewhere in the system.  
The SCLK and SDATA pins of the ADM1032 can be  
interfaced directly to the SMBus of an I/O controller, such  
as the Intel 820 chipset.  
4. Try to minimize the number of copper/solder  
joints, which can cause thermocouple effects.  
Where copper/solder joints are used, make sure  
that they are in both the D+ and Dpath and at the  
same temperature.  
Thermocouple effects should not be a major  
problem since 1°C corresponds to about 200 mV  
and thermocouple voltages are about 3 mV/°C of  
temperature difference. Unless there are two  
thermocouples with a big temperature differential  
between them, thermocouple voltages should be  
much less than 200 mV.  
0.1m F  
V
3V TO 3.6V  
DD  
ADM1032  
TYP 10kW  
D+  
SCLK  
SDATA  
ALERT  
D–  
SMBUS  
CONTROLLER  
5. Place a 0.1 mF bypass capacitor close to the V  
2N3906 SHIELD  
OR  
CPU THERMAL  
DIODE  
DD  
pin. In very noisy environments, place a 1000 pF  
input filter capacitor across D+ and Dclose to the  
ADM1032.  
V
DD  
5V OR 12V  
THERM  
TYP 10kW  
GND  
FAN  
6. If the distance to the remote sensor is more than  
eight inches, the use of twisted pair cable is  
recommended. This works up to about six feet to  
12 feet.  
CONTROL  
CIRCUIT  
FAN  
ENABLE  
Figure 19. Typical Application Circuit  
7. For really long distances (up to 100 feet), use  
shielded twisted pair, such as Belden #8451  
http://onsemi.com  
15