1N4001, 1N4002, 1N4003, 1N4004, 1N4005, 1N4006, 1N4007
MAXIMUM RATINGS
Rating
†Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
†Non−Repetitive Peak Reverse Voltage
(halfwave, single phase, 60 Hz)
†RMS Reverse Voltage
†Average Rectified Forward Current
(single phase, resistive load,
60 Hz, T
A
= 75°C)
†Non−Repetitive Peak Surge Current
(surge applied at rated load conditions)
Operating and Storage Junction
Temperature Range
Symbol
V
RRM
V
RWM
V
R
V
RSM
V
R(RMS)
I
O
1N4001
50
1N4002
100
1N4003
200
1N4004
400
1N4005
600
1N4006
800
1N4007
1000
Unit
V
60
35
120
70
240
140
480
280
1.0
720
420
1000
560
1200
700
V
V
A
I
FSM
T
J
T
stg
30 (for 1 cycle)
−65
to +175
A
°C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
†Indicates JEDEC Registered Data
THERMAL CHARACTERISTICS
Rating
Maximum Thermal Resistance, Junction−to−Ambient
Symbol
R
qJA
Max
Note 1
Unit
°C/W
ELECTRICAL CHARACTERISTICS
†
Rating
Maximum Instantaneous Forward Voltage Drop, (i
F
= 1.0 Amp, T
J
= 25°C)
Maximum Full−Cycle Average Forward Voltage Drop, (I
O
= 1.0 Amp, T
L
= 75°C, 1 inch leads)
Maximum Reverse Current (rated DC voltage)
(T
J
= 25°C)
(T
J
= 100°C)
Maximum Full−Cycle Average Reverse Current, (I
O
= 1.0 Amp, T
L
= 75°C, 1 inch leads)
†Indicates JEDEC Registered Data
Symbol
v
F
V
F(AV)
I
R
Typ
0.93
−
0.05
1.0
−
Max
1.1
0.8
10
50
30
Unit
V
V
mA
I
R(AV)
mA
http://onsemi.com
2