 浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第15页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第16页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第17页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第18页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第20页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第21页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第22页浏览型号ZEN-STARTER02-V2的Datasheet PDF文件第23页  
Operation  
Bits  
Name  
Symbol  
Bit  
No. of  
Operation  
Details  
(See  
note 1.)  
addresses points  
Input bits  
I
I0 to Ib  
12  
12  
8
Reflect the ON/OFF status of the input devices connected to the input  
terminals on the CPU Unit.  
(See note 2.)  
---  
Expansion input bits  
Output bits  
X
Q
Y
M
H
T
X0 to Xb  
Reflect the ON/OFF status of the input devices connected to the input  
terminals on the Expansion I/O Units.  
Q0 to Q7  
(See note 2.)  
The ON/OFF status of these output bits is used to control the output devices  
connected to the output terminals on the CPU Unit.  
Expansion output bits  
Work bits  
Y0 to Yb  
M0 to Mf  
H0 to Hf  
T0 to Tf  
12  
16  
16  
16  
The ON/OFF status of these output bits is used to control the output devices  
connected to the output terminals on the Expansion I/O Units.  
1
Work bits can be used only within the ZEN program. I/Os for external devices  
cannot be made (i.e., all I/O is internal).  
Holding bits  
Timers  
Used the same as the work bits. However, if the power to the ZEN is turned  
OFF, these bits also maintain the previous ON/OFF status.  
X: ON-delay timer  
Functions are  
selected from the  
screen when  
parameter settings  
are made.  
Time units can be selected  
from the following:  
0.01-s unit: 0.01 to 99.99 s  
min/s unit: 00 min 01 s to  
99 min 59 s  
: OFF-delay timer  
O: One-shot pulse  
timer  
2
h/s unit:  
00 h 01 min to  
99 h 59 min  
F: Flashing pulse  
timer  
W: Twin timer  
Holding timers  
#
#0 to #7  
8
Hold the present value being counted even if the trigger input or power supply  
is turned OFF and continue timing when the trigger input or power is restored.  
3
4
Counters  
C
F
C0 to Cf  
F0  
16  
1
Reversible 4-digit counters that can be incremented and decremented.  
8-digit counter  
Reversible 8-digit counters that can be incremented and decremented.  
CPU Units with DC power supply support a high-speed counter up to 150 Hz.  
For details, refer to “8-digit Counter Operation” on page 21.  
5
Weekly timers  
(See note 3.)  
@
*
@0 to @f  
*0 to *f  
16  
16  
16  
4
Turn ON and OFF during specified times on specified days.  
6
7
8
9
Calendar timers  
(See note 3.)  
Turn ON and OFF between specified dates.  
Display bits  
(See note 3.)  
D
D0 to Df  
A0 to A3  
P0 to Pf  
Display user-specified messages, times, timer/counter present values, or  
analog-converted values.  
Analog comparator bits A  
Used as program input conditions to output analog comparator comparison  
results. These bits can be used only for CPU Units with DC power supply.  
Timer/counter  
comparator bits  
P
16  
Compare the present values of timers (T), holding timers (#), and counters  
(C). Comparison can be made between the same two counters or timers, or  
with constants.  
10  
8-digit counter  
comparator bits  
G
B
G0 to G3  
B0 to B7  
4
8
Used to compare the present values of 8-digit counters (F) and output the  
comparison results.  
11  
12  
Button input bits  
(See note 3.)  
Used as program input conditions and turn ON when operation buttons are  
pressed in RUN Mode.  
Note: 1. For details, refer to the indicated item numbers on the following pages.  
2. CPU Units with 10 I/O points have 6 input bits (I0 to I5) and 4 output bits (Q0 to Q3). Output bit Q3 of Communications-type CPU Units,  
however, cannot be output externally. It can be used as a work bit.  
3. These input bits are not supported by LED-type CPU Units without display.  
1. Additional Bit Output Functions  
[: Normal  
Set/Reset operation  
A: Alternate  
S: Set  
R: Reset  
I0  
I1  
I2  
I3  
[Q0  
SQ1  
RQ1  
AQ2  
I0  
I1  
I2  
I3  
Q0  
Q1  
Q1  
Q2  
Q0 will turn ON or OFF depending Q1 will stay ON once the execution Q1 is forced OFF when the  
Q2 alternates between turning ON  
and OFF when the execution  
condition I3 turns ON.  
on the ON/OFF status of the  
execution condition I0.  
condition I1 has turned ON once. A execution condition I2 is turned  
reset is used to turn Q1 OFF. ON.  
Programmable Relay ZEN V2 Units  
19  