Ratings
Contact
Contact
Rated voltage
NC
ZE-@
ZV-@
ZV2-@
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
XE-@
XV-@
XV2-@
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Note: 1.
2.
3.
4.
15 A
15 A
10 A
0.5 A
0.25 A
15 A
15 A
15 A
10 A
3A
Non-inductive load
Resistive load
NO
3A
2.5 A
1.5 A
0.5 A
0.25 A
3A
3A
3A
3A
1.5 A
3A
3A
3A
1.5 A
0.75 A
Lamp load
NC
NO
1.5 A
1.25 A
0.75 A
NC
15 A
15 A
6A
0.05 A
0.03 A
15 A
15 A
10 A
7.5 A
2A
15 A
10 A
10 A
6A
1.5 A
Inductive load
Inductive load
NO
5A
3A
1.5 A
0.05 A
0.03 A
10 A
10 A
10 A
6A
2A
10 A
10 A
6A
4A
1A
Motor load
NC
NO
2.5 A
1.5 A
0.75 A
The above figures are for standard currents.
Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
Lamp load has an inrush current of 10 times the steady-state current.
Motor load has an inrush current of 6 times the steady-state current.
NC
NO
30 A max.
15 A max.
Limit
Switches
Inrush current
■
Characteristics
Degree of protection
Durability (see note 3)
IP65 (see note 2)
Mechanical:
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Electrical:
Z@: 500,000 operations min., for 15 A, 250 VAC resistive load
X@: 100,000 operations min., for 10 A, 125 VDC resistive load
Plunger type: 0.01 mm to 0.5 m/s
Lever type: 0.02 mm to 0.5 m/s
Mechanical: 120 operations/min
Electrical: 20 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
50° max.
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between each
terminal and non-current-carrying metal part (1,500 VAC for Z@ models and X@ models)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 4)
Destruction: 1,000 m/s
2
min.
Malfunction: 100 m/s
2
min. (see note 5), 50 m/s
2
min. (see note 6)
Operating: –10°C to 80°C (with no icing)
Operating: General-purpose type: 85% max.
Sealed type:
95% max.
Approx. 260 to 280 g
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Dielectric strength
Vibration resistance
Shock resistance (see note 4)
Ambient temperature (see note 1)
Ambient humidity
Weight
Note: 1.
The above figures are initial values.
2.
IP65 for
@E-N
models and IP60 for
@E-Q
models.
3.
The values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON
sales representative for more detailed information on other operating environments.
4.
At the operation limit positions.
5.
Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.
6.
Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.
Enclosed Switches
ZE/ZV/XE/XV
F-121